Description
EN 50306 Thin Wall Instrumentation & Control Cable
FIREROL FRL-TW-05MP-ESW-IOS
<br />
Application<br />
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor.<br />
-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.<br />
<br />
Construction<br />
Conductor<br />
Tinned annealed copper wires as defined in EN 50306-2<br />
<br />
Insulation<br />
LSZH special compound<br />
<br />
Overall screen<br />
Tinned annealed copper wires<br />
<br />
Pair screen<br />
Individual screened and sheathed. Screened according to EN 50306-3; Sheathed according to EN 50306-3 (S1. S2)<br />
<br />
Pair Identification<br />
Pairs numbered according to EN 50306-4<br />
<br />
Outer sheath<br />
LSZH special compound (S2. EM 101 - EM 104)<br />
<br />
Electrical & Mechanical Properties<br />
Nominal Voltage<br />
300/500 V<br />
<br />
Maximum Conductor Temperature<br />
+90/+105 deg (fixed installation)<br />
<br />
Minimum Permissible Ambient Temperature<br />
-25/-40 deg (fixed installation)<br />
<br />
Bending Radius<br />
10 x Overall Diameter<br />
<br />
Chemical & Environmental Properties<br />
EN 60684-2<br />
No fluorine<br />
<br />
EN 50305; EN 60811-2-1<br />
Resistance to oil & fuel<br />
<br />
EN 50305<br />
Resistance to ozone<br />
<br />
Fire Performance for rolling stock application<br />
EN 50306-2<br />
Hazard levels HL1, HL2/HL3, HL4<br />
<br />
DIN 5510-2<br />
Protection level 1/2/3/4<br />
<br />
BS 6853<br />
Interior use 1a, 1b, II; Exterior use 1a, 1b, II<br />
<br />
NF F 16-101<br />
FO<br />
<br />
Fire Performance in general<br />
EN 50265-2-1; IEC 60332-1; BS 4066-1<br />
Vertical flame propogation for a single insulated wire or cable<br />
<br />
EN 50266-2-4 + EN 50305; IEC 60332-3C;<br />
Fire propagation of bunched wires and cables;<br />
<br />
VDE 0472 Teil 804; BS 4066-3; NFC 32070<br />
<br />
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816<br />
Smoke density<br />
<br />
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815<br />
Halogen Free<br />
<br />
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813<br />
Corrosivity of gases (Acidity & Conductivity)<br />
<br />
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853<br />
Toxicity index<br />
<br />
NFF 16101; NFF 63808; BS6853<br />
Smoke index<br />
<br />
FRL-TW-05MP-ESW-IOS 300/500 V<br />
NUMBER OF CORES AND NOMINAL CROSS SECTION(MM2); MINIMUM THICKNESS OF SHEATH AT ANY POINT(MM); OVERALL DIAMETER MIN.(MM) MAX.(MM); WEIGHT(KG/KM)<br />
2 x 2 x 0.5 1.0 10.1 11.3 100<br />
3 x 2 x 0.5 1.0 10.8 12.0 150<br />
4 x 2 x 0.5 1.0 11.8 13.0 180<br />
7 x 2 x 0.5 1.0 13.9 15.5 270<br />
<br />
2 x 2 x 0.75 1.0 10.9 12.1 120<br />
3 x 2 x 0.75 1.0 11.6 12.8 170<br />
4 x 2 x 0.75 1.0 12.8 14.0 220<br />
7 x 2 x 0.75 1.0 15.1 16.7 330<br />
<br />
2 x 2 x 1.0 1.0 11.3 12.5 130<br />
3 x 2 x 1.0 1.0 12.0 13.2 190<br />
4 x 2 x 1.0 1.0 13.2 14.4 235<br />
7 x 2 x 1.0 1.0 15.7 17.3 370<br />
<br />
2 x 2 x 1.5 1.0 13.3 14.5 180<br />
3 x 2 x 1.5 1.0 14.0 15.6 260<br />
4 x 2 x 1.5 1.0 15.5 17.1 340<br />
7 x 2 x 1.5 1.0 18.7 20.3 540
- EN 50306 Thin Wall Instrumentation & Control Cables 300/500 V
- LSZH
- multi pair screened with exposed Standard Wall sheath
- FIREROL FRL-TW-05MP-ESW-IOS
Production Capacity:
100000000
Delivery Timeframe:
Within 30 Days
Incoterms:
Not informedPackaging Details:
Not informed
More about
CALEDONIAN CABLES LIMITED
50-100
Employees
1M - 2M
Sales volume (USD)
Not informed
Year
Established
Business type
- Industry / Manufacturer
Keywords
- cables
- wires
- Belden Equivalent Cable
- BS Cable
- Automotive Cable
- Bus Cable
- Coaxial Cable
- Data Cable
- Fiber Optic Cable
- Fire Retardant Cable
- Industrial Cable
- Instrumentation Cable
- Railway Cable
- Offshore&Marine Cable
- Thermocouple Cable
- Rolling Stock Cable
- Telephone Cable Ver Mais
Contact and location
- Penny Zou
- +86 21 xxxxxxxx
- Shanghai / Shanghai | China